Rigol DS1204B Especificações Página 73

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 152
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 72
Command Systems RIGOL
Programming Guide for DS1000B Series
2-61
10. :MEASure:OVERshoot?
Command Format:
:MEASure:OVERshoot? [<source>]
Function:
The command measures the overshoot value of signal from <source>. The
<source> may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 8.000e003, and the unit is V.
11. :MEASure:PREShoot?
Command Format:
:MEASure:PREShoot? [<source>]
Function:
The command measures the preshoot value of signal from <source>. The
<source> may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 8.000e-003, and the unit is V.
12. :MEASure:FREQuency?
Command Format:
:MEASure:FREQuency? [<source>]
Function:
The command measures the frequency of signal from <source>. The <source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 1.000e003, and the unit is Hz.
Vista de página 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 151 152

Comentários a estes Manuais

Sem comentários