Example 2 : Elimination of test impedance error
Purpose: To eliminate impedance error of test down-lead
In measuring the smaller resistance, the impedance of test down-lead leads to error.
So uses should eliminate the impedance error of test down-lead before measuring.
The programming steps:
0 *RST /*reset */
1 *IDN? /*query equipment ID*/
2 :function:resistance /*turn on 2WR measue function*/
3 :measure:resistance□MIN /*set the two circuits resistance range as 200Ω*/
4 /*at the times, please connect the red and black table T for measuring
resistance*/
5 :calculate:function□AVERAGE /*turn on AVERAGE calculation function*/
6 :calculate:statistic:average? /*query the average resistance*/
7 /*note the resistance value: 3.302198e-01 */
8 :calculate:function□NULL /*turn on NULL calculation function*/
9 :calculate:NULL:offset? /*query the NULL calculation offset, and use it for
examining the equipment*/
10 /*here , the return value is 0*/
11 :calculate:NULL:offset□0.330219 /*set offset as 0.330219*/
12 :calculate:function□NULL /* set NULL calculation with the above
offset*/
13 :calculate:function□AVERAGE /*turn on AVERAGE calculation function*/
14 :calculate:statistic:average? /*query the average resistance*/
15 /*the returned value is 3.173456e-04*/
Remark:
1. Before sending the fifth command, to do send the fourth commad.
2. The fifteenth line shows: the above calculation lowers the error three orders. And
the test to eliminate the impedance error of test down-lead is successful.