RIGOL Chapter 2 Command System
Programming Guide for DM3000
2-32
Syntax
:UTILity:INTErface:LAN:DHCP?
:UTILity:INTErface:LAN:DHCP {ON|OFF|1|0}
Function
Turns on or off the DHCP settings.
The query returns ON or OFF.
Default
ON
Syntax
:UTILity:INTErface:LAN:AUTOip?
:UTILity:INTErface:LAN:AUTOip {ON|OFF|1|0}
Function
Turns on or off the IP settings.
The query returns ON or OFF.
Default
ON
Syntax
:UTILity:INTErface:LAN:MANUip?
:UTILity:INTErface:LAN:MANUip {ON|OFF|1|0}
Function
Turns on or off the Manual IP settings.
Default
ON
Syntax
:UTILity:INTErface:LAN:IP?
:UTILity:INTErface:LAN:IP
<ip_address>
Function
Defines the IP address of the meter.
Explanation
The format of
<ip_address>
is nnn.nnn.nnn.nnn. The first
nnn ranges from 0 to 223 (except 127) and the others range
from 0 to 255.
The IP address configuration type should be Manual and both
DHCP and Auto Ip should be disabled while you use this
command.
Default
168.254.0.238
Syntax
:UTILity:INTErface:LAN:MASK?
:UTILity:INTErface:LAN:MASK
<ip_address>
Function
Defines the subnet mask of the network that currently connected to
the meter.