Rigol DM3058 Especificações Página 166

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 264
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 165
RIGOL
Programming Guide for DM3058
ACI measurement.
Before sending the command, run the command [SENSe:]CURRent:AC:NULL
[:STATe]ON‖ to enable NULL function.
Return Format:
The query returns the NULL value of ACI measurement.
4. [SENSe:]CURRent:AC:PEAK:STATe
Command Format:
[SENSe:]CURRent:AC:PEAK:STATe{ON|OFF}
[SENSe:]CURRent:AC:PEAK:STATe?
Function:
The command sets or queries the enable state of ACI peak-to-peak measuring
function.
Explanations:
[SENSe:]CURRent:AC:PEAK:STATe {ON|OFF}: Enable or disable ACI
peak-to-peak measuring function.
[SENSe:]CURRent:AC:PEAK:STATe?: Query the enable state of ACI peak-to-peak
measuring function.
The command ―[SENSe:]CURRent:AC:NULL:VALue‖ can be used to set the ACI
peak-to-peak value.
Return Format:
The command returns the enable state of ACI peak-to-peak measuring function.
5. [SENSe:]CURRent:AC:RANGe:AUTO
Command Format:
[SENSe:]CURRent:AC:RANGe:AUTO{ON|OFF}
[SENSe:]CURRent:AC:RANGe:AUTO?
Function:
The command sets or queries the enable state of ACI autorange function.
Vista de página 165