RIGOL 2 Command System
2-526 DS2000 Programming Guide
2-526
:TRIGger:IIC:ADDRess
Syntax
:TRIGger:IIC:ADDRess <adr>
:TRIGger:IIC:ADDRess?
Description
Set the address value in IIC trigger when the trigger condition is Address or A&D.
Query the current address value in IIC trigger when the trigger condition is Address
or A&D.
Parameter
Name Type Range Default
<adr> Integer 0 to 2
n
1: 0 to 127 , 0 to 255 or 0 to 1023 1
Note: in the expression 2
n
- 1, n is the current address bits (refer to the :TRIGger:IIC:AWIDth
command).
Explanation
To set the IIC trigger condition, refer to the
:TRIGger:IIC:WHEN command.
Return Format
The query returns an integer.
Example
:TRIGger:IIC:ADDRess 100
The query returns 100.