Rigol DS2000A Series Especificações Página 191

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 390
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 190
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-175
:MEASure:PREShoot
Syntax 1
:MEASure:PREShoot <chan>
Description 1
Enable the preshoot measurement function of the specified channel.
Syntax 2
:MEASure:PREShoot? <chan>
Description 2
Enable the preshoot measurement function of the specified channel and return the measurement result.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the preshoot measurement result in scientific notation. When the measurement result
is invalid, the query returns 9.9e37.
Example
:MEASure:PREShoot CHANnel1
:MEASure:PREShoot? CHANnel1
You can use the following commands to enable the preshoot measurement function of the specified
channel and the statistic function of the measurement results as well as query the statistic maximum
value, minimum value, current value, average value and standard deviation of the preshoot measurement
results.
:MEASure:PREShoot:SMAXimum
:MEASure:PREShoot:SMINimum
:MEASure:PREShoot:SCURrent
:MEASure:PREShoot:SAVerage
:MEASure:PREShoot:SDEViation
Vista de página 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 389 390

Comentários a estes Manuais

Sem comentários