2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-277
:TRIGger:SWEep
Syntax
:TRIGger:SWEep <sweep>
:TRIGger:SWEep?
Description
Set or query the trigger mode.
Parameter
Name Type Range Default
<sweep> Discrete {AUTO|NORMal|SINGle} AUTO
Explanation
AUTO:
After this mode is selected, the oscilloscope starts searching for trigger signals that meet the
specified condition. If trigger signals that meet the specified condition are found, “T’D” is displayed
at the upper-left corner of the user interface and stable waveform is displayed. Otherwise, “AUTOis
displayed and unstable waveform is displayed.
NORMal:
After this mode is selected, the oscilloscope enters the wait-for-trigger state and starts searching for
trigger signals that meet the specified condition. If trigger signals that meet the specified condition
are found, T’D” is displayed in the running status bar and stable waveform is displayed. Otherwise,
WAITis displayed and the waveform of the last trigger (there is a last trigger) or no waveform
(there is not a last trigger) is displayed.
SINGle:
When this mode is selected, the backlight of SINGLE turns on. The oscilloscope enters the
wait-for-trigger state and starts searching for trigger signals that meet the specified condition. If
trigger signals that meet the specified condition are found, “T’D” is displayed in the running status
bar and stable waveform is displayed. Then, the oscilloscope stops sweeping, the backlight of
RUN/STOP turns on and STOPis displayed in the running status bar. Otherwise, WAIT” is
displayed in the running status bar and no waveform is displayed.
Return Format
The query returns AUTO, NORM or SING.