2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-205
:MEASure:VTOP
Syntax 1
:MEASure:VTOP <chan>
Description 1
Enable the amplitude top value measurement function of the specified channel.
Syntax 2
:MEASure:VTOP? <chan>
Description 2
Enable the amplitude top value measurement function of the specified channel and return the
measurement result.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Explanation
The unit is determined by the unit selected for the signal source channel (refer to
the
:CHANnel<n>:UNITs command).
Return Format
The query returns the amplitude top value measurement result in scientific notation. When the
measurement result is invalid, the query returns 9.9e37.
Example
:MEASure:VTOP CHANnel1
:MEASure:VTOP? CHANnel1
You can use the following commands to enable the amplitude top value measurement function of the
specified channel and the statistic function of the measurement results as well as query the statistic
maximum value, minimum value, current value, average value and standard deviation of the amplitude
top measurement results.
:MEASure:VTOP:SMAXimum
:MEASure:VTOP:SMINimum
:MEASure:VTOP:SCURrent
:MEASure:VTOP:SAVerage
:MEASure:VTOP:SDEViation