RIGOL Chapter 2 Command System
2-110 DS1000Z Programming Guide
:TRIGger:WINDows:POSition
Syntax :TRIGger:WINDows:POSition <pos>
:TRIGger:WINDows:POSition?
Description
Set or query the trigger position in windows trigger.
Parameter
Name
Type
Range
Default
<type>
Discrete
{EXIT|ENTER|TIMe}
ENTER
Explanation EXIT: trigger when the input signal exits the specified trigger level range.
ENTER: trigger when the trigger signal enters the specified trigger level range.
TIMe: used to specify the hold time of the input signal after entering the specified
trigger level range. The instrument triggers when the accumulated hold time equals
the windows time.
Return
Format
The query returns EXIT, ENTER or TIM.
Example
:TRIGger:WINDows:POSition ENTER
:TRIGger:WINDows:TIMe
Syntax :TRIGger:WINDows:TIMe <NR3>
:TRIGger:WINDows:TIMe?
Description
Set or query the hold time in windows trigger.
Parameter
Name
Type
Range
Default
<NR3>
Real
8ns to 10s
1μs
Return
Format
The query returns the hold time in scientific notation.
Example
:TRIGger:WINDows:TIMe 0.002 /*Set the hold time to 2ms*/
:TRIGger:WINDows:TIMe? /*The query returns 2.000000e-03*/