Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-37
:MATH:SOURce2
Syntax :MATH:SOURce2 <src>
Set or query the source of the math operation.
Parameter
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
For the operations which needs two source, this command is used to set the source B.
Return
The query returns CHAN1, CHAN2, CHAN3 or CHAN4.
:MATH:SCALe
Syntax :MATH:SCALe <scale>
Description Set or query the vertical scale of the operation result. The unit dependents on the
operator currently selected and the unit selected by the source.
Parameter
<scale> Real The max range is from 1p to 5T (in 1-2-5 step) 1.00V
Explanation The range of the vertical scale is related to the operator currently selected and the vertical
scale of the source channel. For the integration (intg) and differential (diff) operations, it
is also related to the current horizontal timebase.
Return
The query returns the vertical scale of the operation result in scientific notation.
Example
:MATH:SCALe 2 /*Set the vertical scale to 2*/
:MATH:SCALe? /*The query returns 2.000000e+00*/
Related
Command
:CHANnel<n>:SCALe
:CHANnel<n>:UNITs
:MATH:OPERator