Rigol DS1000Z Series Especificações Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 172
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-39
:MATH:FFT:WINDow
Syntax :MATH:FFT:WINDow <wnd>
:MATH:FFT:WINDow?
Description
Set or query the window function of the FFT operation.
Parameter
Name
Type
Range
Default
<wnd> Discrete
{RECTangle|BLACkman|HANNing|HAMMing|
FLATtop|TRIangle}
RECTangle
Explanation Spectral leakage can be considerably decreased when a window function is used.
Different window functions are applicable to measure different waveforms. You need
to select the window function according to different waveforms and their
characteristics.
Return
Format
The query returns RECT, BLAC, HANN, HAMM, FLAT or TRI.
Example
:MATH:FFT:WINDow BLACkman
Related
Command
:MATH:OPERator
:MATH:FFT:SPLit
Syntax :MATH:FFT:SPLit <bool>
:MATH:FFT:SPLit?
Description Enable or disable the half display mode of the FFT operation, or query the status of the
split display mode of the FFT operation.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
1|ON
Explanation Enable the half display mode: the source channel and the FFT operation results are
displayed separately. The time domain and frequency domain signals are displayed
clearly.
Disable the half display mode (full display mode): the source channel and the FFT
operation results are displayed in the same window to view the frequency spectrum
more clearly and to perform more precise measurement.
Return
Format
The query returns 0 or 1.
Example
:MATH:FFT:SPLit OFF
Related
Command
:MATH:OPERator
Vista de página 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 171 172

Comentários a estes Manuais

Sem comentários